Marine Container load box (super power intelligent load box) ALB-D smart three-phase AC load box (diesel generator test load box)
Information Name: | Marine Container load box (super power intelligent load box) ALB-D smart three-phase AC load box (diesel generator test load box) |
Published: | 2015-05-30 |
Validity: | 365 |
Specifications: | ALB-DT |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Marine Container load box (super power intelligent load box) Product Description: Fuel ALB-DT Marine Container load box (super power intelligent load box) Marine generators mostly diesel, diesel at less than 50% load or prolonged will result in insufficient fuel, coke, machine efficiency is reduced, resulting in difficulty in starting, lack of motivation, increased fuel consumption, resulting in premature opening cylinder repair scrapped under no-load conditions. The load box is ideal dummy load generator. ALB-DT Marine Container load box (super power intelligent load box) is power, frequency, voltage, current, power factor, stability and other parameters of the generator ideal testing equipment to test the generator. ALB-D smart three-phase AC load box that we provide (diesel generator test load box) can accurately detect the output power and load capacity with all kinds of turbines. Marine Container load box (super power intelligent load box) Features: 1, stainless steel stationary container design. 2, newly installed diesel generator project acceptance, testing its ability to meet the design requirements. 3, installation of diesel generator muffler noise reduction equipment, testing the output power can meet the communications equipment needed for the operation. 4, diesel generators after repair, test the output power, load capacity and other performance indicators to meet the requirements. 5, routine maintenance of diesel generators routine testing, according to the new regulations issued by the communication power supply maintenance requirements of diesel generators every six months to load test machine for 15-30 minutes. Marine Container load box (super power intelligent load box) Applications: shipbuilding, railways, electricity, communication base station power station load testing. Marine Container load box (super power intelligent load box) the selection of reference: Name Marine Container load box (super power intelligent load box) Model ALB-DT1000K ALB-DT2000K ALB-DT2MK / 3 ALB-DT2MK / 6 ALB-DT2MK / 10 Technical Specifications Maximum load box discharge power 1000KW 2000KW 2000KW 2000KW 2000KW discharge voltage range AC 400V / 220V three-phase four-wire AC 400V / 230V three-phase four-wire three-phase four-wire AC 3300V AC 6600V three-phase four-wire AC 10.5KV phase four-wire power factor 1.0 1.0 1.0 1.0 1.0 frequency range 50HZ / 60HZ 50HZ / 60HZ 50HZ 50HZ 50HZ power measurement range 0-1000kw 0-2000kw 0-100kw 0-500kw 0-1000kw regulation accuracy 1KW 0-2000kw 1KW 1KW 1KW control in the form of AC contactor AC contactor high voltage vacuum contactors high voltage vacuum contactors high voltage vacuum contactors Three-phase power supply + N AC 380V three-phase + N AC 380V three-phase + N AC 380V three-phase + N AC 380V three-phase + N AC 380V LED display digital instrument + color display LED digital meter + color display Optional Optional Optional overvoltage protection device, high temperature alarm, fan failure protection over voltage, high temperature alarm, fan failure protection over voltage, temperature alarm, fan overvoltage fault protection, high temperature alarm, fan failure protection over voltage, high temperature alarm, fault protection Cooling fan forced air forced air forced air forced air forced air Dimensions 2000 * 1500 * 36,002,000 * 2000 * 6000 2000 * 2000 * 6000 2000 * 2000 * 6000 2000 * 2000 * 6000 Optional features manually type / computer remote control manually type / computer remote control remote computer control the remote computer control the remote computer control measurement parameter measurement error voltage ± ( 0.25% of reading + 0.25% of range) ± (0.25% of reading + 0.25% of range) instrument matching instrument matching instrument matching current ± (0.25% of reading + 0.25% of range) ± (0.25% of reading + 0.25% of range) Power Power Factor = 1.0: ± (0.25% of reading + 0.25% of range) Power factor = 1.0: ± (0.25% of reading + 0.25% of range) Power factor ± 0.02 ± 0.02 ± 0.1Hz ± 0.1Hz frequency running time ± 2 seconds per hour h ± 2 秒 Electrical Power factor = 1.0: ± (0.25% of reading + 0.25% of range) Power factor = 0.5: ± (0.5% of reading + 0.5% of range) Power factor = 1.0: ± (0.25% of reading + 0.25% of range) Power factor = 0.5: ± (0.5% of reading + 0.5% of range) harmonic analysis 2-50 2-50 load box main function 1. Detection UPS, EPS, diesel generators, gasoline generators, inverters, transformers and other equipment output power and load capacity 2. The host system can automatically detect the three-phase phase voltage, line voltage, phase current, power factor, frequency, load time, power hours, etc. 3. You can set the parameters: voltage upper and the lower limit of the total power, load time, storage space, time, date and other parameters 4. perseverance power load, the band load, sudden unload function, and can submit various forms of test report 5. The power band load function: realization from 0%, 25%, 50%, 75%, 100%, 110% automatic loading and unloading functions of the power section 6. power sudden load unload function 7. undervoltage, overvoltage, overcurrent, high temperature, alarm shutdown 8. Data storage: Data include: three-phase voltage, current, power factor, frequency, power hour, stop reasons, etc. 9. Each parameter can be achieved independently control the power level, the sudden increase in functionality alone achieve. Single use and multi-parallel functions and operations 10. The display of the parameters and the same real-time test data with the data analysis 11. The printing software, print the discharge curve analysis, automated generation of test reports, and can lead into EXCEL or WORD 12. Analysis Software It can display: voltage, current, temperature, frequency, power, power factor, waveform, data tables and other equipment with a manual load curve 13 and the remote computer is loaded with features to achieve a variety of modes of operation |
Admin>>>
You are the 15001 visitor
Copyright © GuangDong ICP No. 10089450, Ningbo Electrical Equipment Co., Ltd. Air Mao All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15001 visitor
Copyright © GuangDong ICP No. 10089450, Ningbo Electrical Equipment Co., Ltd. Air Mao All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility