Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13776444
- Product Categories
- Friendly Links
- home > Supply > DC adjustable mobile intelligent load box load box 200kW DC battery, DC power maintenance and capacity testing equipment
DC adjustable mobile intelligent load box load box 200kW DC battery, DC power maintenance and capacity testing equipment
Information Name: | DC adjustable mobile intelligent load box load box 200kW DC battery, DC power maintenance and capacity testing equipment |
Published: | 2015-05-30 |
Validity: | 365 |
Specifications: | PLD-C8 |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Overview DC adjustable moving load box: The load box is designed for telecommunications, power, railways, battery manufacturers and other sectors of the battery pack, a DC power supply for maintenance and capacity test use. Instrument design, functionality, small size, high reliability, easy operation, power part of special components and patented technology to produce power, no fire, safety and long life. ? DC adjustable load-moving selection box Ordering Information: 1, special specifications can be customized (; rated current of 10A-2000A can be produced voltage level DC2V-800V); claim 2, DC adjustable load boxes to move non-standard build Please provide the following parameters before ordering:.... ① Rated voltage (DC12V, 48V, 110V, 220V, etc.); ② frequency parameter (50HZ / 60HZ etc.); ③ Rated power KW / Rated current A; ④ minimum power Stepping requirements / current minimum step requirements;. ⑤ environmental conditions, operating mode (the default is long-term work system). ? The main technical specifications of the DC adjustable moving load box: test voltage DC2V / 5V / 12V / 24V / 30V / 36V / 48V / 110V / 220V / 440V / 600V / 800V rated power installed capacity 3KW 3KW (0.1K, 0.2K, 0.3K, 0.4K, 1K, 1K) 5KW 5KW (0.1K, 0.2K, 0.3K, 0.4K, 1K, 1K, 2K) 10KW 11KW (0.1K, 0.2K, 0.3K, 0.4K, 1K, 2K, 3K, 4K) 20KW 21KW (0.1K, 0.2K, 0.3K, 0.4K, 1K, 2K, 4K, 5K, 8K) 30KW 31KW (0.1K, 0.2K, 0.3K, 0.4K, 1K, 2K, 4K, 8K, 15K) 50KW 51KW (0.1K, 0.2K, 0.2K, 0.5K, 1K, 2K, 2K, 5K, 10K, 10K, 20K) 100KW 100KW (1K, 2K, 2K, 5K, 10K, 10K, 20K, 50K) 200KW 200KW (1K, 2K, 2K, 5K, 10K, 10K, 20K, 50K, 100K) 500KW 500KW (1K, 2K, 2K, 5K, 10K, 10K, 20K, 50K, 100K, 100K, 200K) 500KW or more can be customized according to customer requirements, can be made more independent and machine can also use the power supply single-phase AC 220V or 380V three-phase control manual control, power continuously step (precision adjustable) Cooling system Forced air / Nature Air-cooled LED display meter / multifunction measuring instruments (current, voltage, power, frequency, power factor), precision: 0.5 Optional features A Type: Manual control type B type: remote control / computer control recommended specifications -100KW? DC Intelligent load box (Main features and functions) 1, the test parameters: measure voltage, current, power and other basic functions. 2, communications bus: CAN bus with real-time power control system acceptable regulatory signals, fast response. 3, automatic control: The system has automatic loading function, gradual loading from no load to 25% of rated load, 50%, 75%, 100%, and then load this classification progressively reduced from 100 percent load; (software optional) 4, load indicator: with a corresponding indicator light, fault indicator on the front panel, allowing users to work status of the device at a glance. 5, PC software features: ① fan starts, set loading and unloading, and the detection voltage, current, power and other basic functions. ② phase load function, can be 25%, 50%, 75%, 100% phase load, the percentage can be independently set, load time can be set arbitrarily. ③ PC monitoring function: PC with real-time monitoring capabilities, real-time parameters can be saved, no matter which way through loaded, can collect all the data, and generate a variety of curve tables, or direct printing. (Software optional) 6, the data save interval: Steady Data minimum resolution time is 2S, transient data minimum resolution time is 40US. (Software optional) 7, protection function: protection features temperature detection protection, overvoltage protection, overcurrent protection, if an exception host immediately cut off the load, to protect the power supply and the load equipment. 8. Emergency stop: loaded with emergency stop function, to ensure that equipment in a particular situation, it may unload, ensure the safety of the device and the power supply. 9, intelligent design: intelligent control, automatic test power various parameters. The power supply provides a scientific means of detection. 10, power components and cooling section (resistive load): A new power components, thermal resistance and seal mounted in a stainless steel tube, external heat sink pipe with insulation, moisture-proof, corrosion resistance, heat resistance, high insulation safe and reliable. Resistive element power density, three-phase current balance, no red-hot phenomenon, independent cooling fan, ensures heat dissipation and life of the entire system. The load overcomes the water resistance test system can not accurately control the size of the resistance, boiling water is easy, easy to scale; difficult to control and so on. Water resistance of the upgrading of products, the product safety, low maintenance costs. Low noise, strong overload. |
Admin>>>
You are the 15001 visitor
Copyright © GuangDong ICP No. 10089450, Ningbo Electrical Equipment Co., Ltd. Air Mao All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15001 visitor
Copyright © GuangDong ICP No. 10089450, Ningbo Electrical Equipment Co., Ltd. Air Mao All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility