Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13776444
- Product Categories
- Friendly Links
- home > Supply > AC adjustable moving load box UPS (uninterruptible power supply) and turbine performance testing, burn-in test
AC adjustable moving load box UPS (uninterruptible power supply) and turbine performance testing, burn-in test
Information Name: | AC adjustable moving load box UPS (uninterruptible power supply) and turbine performance testing, burn-in test |
Published: | 2015-05-30 |
Validity: | 365 |
Specifications: | ALB-SY |
Quantity: | 99.00 |
Price Description: | |
Detailed Product Description: | ? AC adjustable moving load box Overview: The load box is mainly used for electric power, telecommunications and other sectors and manufacturers of power-line UPS (uninterruptible power supply) and performance test generator sets, aging and other occasions. It is a device with a carrying capacity of important practical testing and maintenance of equipment. Its application effectively avoid economic loss reserve units or enterprises failed to start due to the power, but also provide a scientific basis for the new unit with a carrying capacity of detection and acceptance of the new battery. ? AC adjustable load-moving selection box Ordering Information: 1, special specifications can be customized according to customer requirements (optional AC single-phase, three-phase AC, fixed or adjustable resistance, resistive load, inductive load, high and low, IF load, non inductive load). 2, AC adjustable moving load boxes of non-standard custom-made, please provide the following parameters before ordering: ① Rated voltage (three-phase AC 0-400V / 230V, single-phase AC 0-600V, etc.); ② frequency parameter (. 50HZ / 60HZ / 400HZ, etc.); ③ Rated power KW / rated current A;. ④ power requirements of the minimum step / current minimum step requirements;.. ⑤ environmental conditions, operating mode (the default is long-term work system). ? AC adjustable moving load boxes of the main technical parameters: Test voltage three-phase AC 0-380V / single-phase AC 0-220V frequency 50HZ-60HZ Power Factor resistance: 1.0 (inductive, capacitive 0.3-1.0 special specifications according to customer requirements ) Rated power installed capacity 3KW 3KW (0.1K, 0.2K, 0.3K, 0.4K, 1K, 1K) 5KW 5KW (0.1K, 0.2K, 0.3K, 0.4K, 1K, 1K, 2K) 10KW 11KW (0.1K , 0.2K, 0.3K, 0.4K, 1K, 2K, 3K, 4K) 20KW 21KW (0.1K, 0.2K, 0.3K, 0.4K, 1K, 2K, 4K, 5K, 8K) 30KW 31KW (0.1K, 0.2 K, 0.3K, 0.4K, 1K, 2K, 4K, 8K, 15K) 50KW 51KW (0.1K, 0.2K, 0.2K, 0.5K, 1K, 2K, 2K, 5K, 10K, 10K, 20K) 100KW 100KW ( 1K, 2K, 2K, 5K, 10K, 10K, 20K, 50K) 200KW 200KW (1K, 2K, 2K, 5K, 10K, 10K, 20K, 50K, 100K) 500KW 500KW (1K, 2K, 2K, 5K, 10K, 10K, 20K, 50K, 100K, 100K, 200K) 500KW above can be customized according to customer requirements, can be made more independent and machine can also use the power supply single-phase AC 220V or 380V three-phase control manual control, power continuously stepping (high-precision adjustable) forced air cooling system / natural air cooling Display LED meter / multifunction measuring instruments (current, voltage, power, frequency, power factor), precision: 0.5 Optional features A Type: Manual control type B Type: Touch screen control type C Type:? computers and generator tester control type Recommended specifications -500KW AC load box and control systems (main features and functions): A type: manual control type 1, single power of 500KW / AC400V / 50HZ / three-phase four-wire system 2, the manual toggle switch operation, adjustable (1,2,2,5,10,10,20,50,100,100,200KW) within 1-500KW power range, real-time display of three-phase V / I / KW / HZ / PF; 3, simple operation, easy to move, small size. 4, high reliability, long continuous work more than eight hours. 5, load accuracy of less than 3 percent, good heat dissipation, using resistance without red hot. 6, wiring convenient, easy maintenance, safe and reliable. 7, resistance requirements 304 stainless steel, the resistance error is less than 1.5%; 8, the box size as small as possible, but should take into account the requirements of the rain outside the box is placed in good solid and reliable, durable and long service life; 9, Resistance Tolerance Insulation Resistance DC500V 100MΩ or more pressure AC2000V 1 minute per root resistance tube:: Each resistance element ± 1.5%; 10, protection class: IP33; B Type: Touch screen control type 1, with all the features of type A and Claim. 2, the touch-screen remote control or local control load acceleration load and fan start and stop; 3, can display real-time power load conditions and load operating conditions on the touch screen; C Type: computer and generator tester control type 1, with A type 2 All functions and requirements, configure the computer and a generator tester, computer remote or local control load acceleration load and fan start and stop; 3, can display real-time power load conditions and load operating conditions on the computer, test data can be stored printing; |
Admin>>>
You are the 15001 visitor
Copyright © GuangDong ICP No. 10089450, Ningbo Electrical Equipment Co., Ltd. Air Mao All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15001 visitor
Copyright © GuangDong ICP No. 10089450, Ningbo Electrical Equipment Co., Ltd. Air Mao All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility