Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13776444
- Product Categories
- Friendly Links
Information Name: | AC load box to Mao AC relay test load switch power inverter load box dummy load |
Published: | 2015-06-18 |
Validity: | 9999 |
Specifications: | Voltage AC220V-400V, power 6kVA-1000kVA |
Quantity: | 200.00 |
Price Description: | |
Detailed Product Description: | AC load box to Mao AC relay test load switch power inverter load box load box dummy load current market variety, load box manufacturers Products do hype, then how to find one of these numerous information suitable load box it? We generally consider the following factors: 1) much needed power, that is, to measure power generators or UPS much; 2) is still required to be fixed using movable type; 3) what functions you want to load have, is simply to do Load test or to multi-functional, intelligent analysis; 4) load box power component performance is good, long time, not temperature, redness phenomenon. And better thermal stability, temperature resistance have little impact. 5) See the load is not controlled manually or intelligent control, load boxes now are turning intelligent control; 6) See load box is a constant power or constant resistance, constant resistance load box the result will be error; 7) See load ever had, undervoltage, phase protection; 8) See load box is not solid state relay control off, weak control the strong electricity. 8) See separate three-phase load box is not loaded, if the three-phase balanced load phase imbalance can not be tested; 9) to see how much the minimum step load, the most accurate load box load box to Mao single with minimum step is 0.1KW, most of the other single-phase 1KW, 5KW; and 10) to see there is no load electricity quality parameters display that can show what parameters, dynamic parameters can not be calculated steady-state voltage regulation rate; 11) There are no data storage and reporting functions; 12) the load weight and volume. To Mao load box technical parameters ALB-D Series Product Specifications: ALB-D: detecting AC output power and load capacity, the discharge power 0 ~ 30KW, single-phase, three-phase dual; ALB-D-100: detect AC output power and load capacity, the discharge power continuously adjustable 0 ~ 100KW, all intelligent; ALB-D-200: detect AC output power and load capacity, the discharge power continuously adjustable 0 ~ 200KW; ALB-D-300: Detection AC output power and load capacity, discharge 0 ~ 300kw power continuously adjustable; ALB-D-600: detect AC output power and load capacity, discharge 0 ~ 300kw power continuously adjustable; ALB-D-900: detect AC output power and load capacity, discharge 0 ~ 900kw power continuously adjustable; ALB-D-1200: detect AC output power and load capacity, the discharge power continuously adjustable 0 ~ 1200kw; ALB-D-1500: detect AC output power and load capacity, discharge power continuously adjustable 0 ~ 1500kw; ALB-D Series Automatic AC load box Specifications (1000KW above can be customized): Model type power loading way power adjustable range of single-phase minimum step ALB-D Automatic Automatic loading 0-50KW continuously adjustable 1KW ALB-D automatic continuously variable automatic loading 0-100KW 1KW ALB-D automatic continuously variable automatic loading 0-300KW 1KW ALB-D automatic continuously variable automatic loading 0-500KW 1KW ALB-D Auto continuously variable automatic loading 0-1000KW 1KW power AC load box configuration parameter table Model ALB-D Remarks Category 2 hosts, four from the host machine Weight KG: 230KG, Slave: 70KG Volume mm Host: 1200 * 700 * 1100 Slave: 800 * 600 * 1060 Color icons light yellow / black power adjustable range 0 ~ 600KW continuously adjustable minimum resolution 0.1KW single-phase minimum step voltage range 220 ~ 400V 50 Hz frequency range suitable for constant power load intelligently heat Air-cooled power unit Material Alloy redness long run without loading the operating keyboard input protection over and undervoltage, phase protection dual power with fan cooling unload low-pressure alarm relay control 4V DC control input is shorted system voltmeter (error of ± 0.5% V) Ammeter have (error ± 0.5% A) frequency table has (error ± 0.5% f) other display three-phase active power, reactive power, power factor, neutral current Other features voltage logger, frequency loggers, transient adjustment rate, the steady-state load regulation calculation functions independent three-phase load, steady state load mode mutation load generator, UPS, inverters, common mode and machine functions For more detailed parameter configuration , price or other specifications require customized products, please directly contact our business staff! |
Admin>>>
You are the 15001 visitor
Copyright © GuangDong ICP No. 10089450, Ningbo Electrical Equipment Co., Ltd. Air Mao All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15001 visitor
Copyright © GuangDong ICP No. 10089450, Ningbo Electrical Equipment Co., Ltd. Air Mao All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility